From micrograph to model
How a structure is determined by single-particle cryo-EM, using cystinosin as the example.Skip to the structures ↓
- 01
Micrograph
Purified cystinosin is vitrified in a thin layer of ice and imaged at low electron dose. Each particle is a single molecule, barely above the noise.

- 02
Particle picking
Particles are located and extracted from every micrograph. Across a full dataset this yields hundreds of thousands of noisy 2D projections, each in an unknown orientation.
Picks shown here are automated, for illustration.

- 03
2D classification
Particles are aligned and averaged by view. The class averages raise the signal enough to resolve transmembrane helices and the surrounding membrane mimetic, and to discard junk.

- 04
3D reconstruction
Combining the views by their relative orientations yields a three-dimensional density map, here of cystinosin bound to the Fab fragment 3H5, refined to 3.2 Å (EMD-27488).

- 05
Atomic model
An atomic model is built and refined into the density (cystinosin in ochre, the Fab in grey), here capturing a cytosol-open conformation, one state of its alternating-access transport cycle.
Open 8DKE in the 3D viewer